Good mechanical and environmental properties;
Flame retardant (or non-ignition) performance follow requirements of relevant standards;
Cable jacket mechanical and physical properties follow requirements of relevant standards;
Soft, flexible, convenient connection, and support large capacity data transmission;
Follow the requirements of the market and users.
Product Introduce
Fiber cores |
OD (mm) |
Weight (kg/km) |
Tensile Loading (N) |
Crush resistance (N/100mm) |
Mini bending radius (mm) |
Applicable temp range (℃) |
|||
Long |
Short |
Long |
Short |
Dynamic |
Static |
||||
2 |
8.7 |
54 |
200 |
400 |
500 |
1000 |
20D |
10D |
-20~+60 |
4 |
8.7 |
56 |
200 |
400 |
500 |
1000 |
|||
6 |
10.0 |
81 |
300 |
600 |
500 |
1000 |
|||
8 |
11.7 |
108 |
400 |
800 |
500 |
1000 |
|||
10 |
13.3 |
134 |
500 |
1000 |
500 |
1000 |
|||
12 |
15.0 |
183 |
600 |
1200 |
500 |
1000 |
|||
Note: 1, All values in the table are for reference 2, Cable OD and weight in the table are obtained under ф0.9 of buffer fiber outer diameter. |